Product Center
Product Classification
Contact Information
Address: Room 1502, Building 2, No. 39, Shangyi Road, Minhang District, Shanghai
Phone:021-64130068
Mobile:18221910198(same as WeChat)
Fax:021-64135086
Email:asli@shinelong.com
RA-1 flat leaf diffuser
- Commodity name: RA-1 flat leaf diffuser
- Product Description
- Technical parameters
-
Made of aluminum profiles, with surface oxidation treatment. Anodizing, electrostatic spraying, and baking paint are also available to meet decorative requirements.
The flat-blade diffuser features a prominent linear design, suitable for circular air inlets and outlets in indoor spaces or halls. It can also be installed on side walls or ceilings.
The blades are fixed, with a slanted air supply and return air type, and the blades are inclined at 15 degrees.
The maximum length of a single piece is 3 meters. Longer lengths can be achieved through splicing.
Optional accessory: G1 air volume control switch.
Face dimensions = Neck dimensions + 37 -
RA-1 Flat Blade Diffuser Performance Table
Neck Area
Air Speed (m/s)
2
3
4
5
6
7
0.0176m2
Total Pressure Loss (Pa)
4
6
9
16
22.0
30.0
Air Volume (CMH)
127
190
254
318
382
445
Reach Distance (M)
Ceiling Discharge
0.2-0.2
0.8-0.8
1.6-1.7
2.1-2.3
2.5-2.8
3.2-3.8
Wall Discharge
1.2-1.6
1.8-2.8
2.5-3.8
3.2-4.8
4.1-5.4
4.4-6.1
NC
~
~
~
23
28
32
0.0253m2
Air Volume (CMH)
182
273
364
455
546
637
Reach Distance (M)
Ceiling Discharge
0.2-0.2
1.3-1.3
2.1-2.3
2.7-3.0
3.4-3.6
4.0-4.2
Wall Discharge
1.4-2.1
2.2-3.2
3.2-4.1
3.8-5.1
4.4-5.9
5.3-6.8
NC
~
~
~
22
27
31
0.0333m2
Air Volume (CMH)
240
360
480
600
720
840
Reach Distance (M)
Ceiling Discharge
0.6-0.6
1.7-1.7
2.6-2.8
3.3-3.7
4.1-4.4
4.9-5.2
Wall Discharge
1.7-2.3
2.6-3.6
3.7-4.6
4.4-5.9
5.3-6.4
6.0-7.3
NC
~
~
~
22
27
31
0.0424m2
Air Volume (CMH)
305
457
609
761
914
1065
Reach Distance (M)
Ceiling Discharge
0.6-0.6
2.0-2.1
3.0-3.0
3.7-4.1
4.7-4.9
5.5-5.6
Wall Discharge
1.9-2.5
3.1-4.1
4.0-5.0
4.8-5.9
5.9-7.1
6.6-8.1
NC
~
~
~
23
28
32
Note: Air outlet test length is based on 1M.
Note: Reach distance is measured at terminal air speed of 0.5M/S~0.25M/S.
Note: NC value column [-] indicates NC is below 20.
Note: NC value is based on indoor absorption attenuation of 10dB and 10-12 watts.
Note: Tested according to A.D.C. standard.
Note: If used for return air, static pressure loss = total pressure loss * 0.75 and NC value + 5.
Note: When the length changes, the reach distance and NC correction values are as follows:Effective Length (M)
0.5
1
1.5
2
NC
-2
0
+2
+3
Terminal air speed 0.5m/s
0.8
1
1.1
1.2
Terminal air speed 0.25m/s
0.9
1
1.15
1.2
Keywords:
Product Inquiry
Please leave your email address, and our professionals will contact you as soon as possible!