RA 2 Flat Blade Diffuser
- Commodity name: RA 2 Flat Blade Diffuser
- Product Description
- Technical parameters
-
Made of aluminum profiles, with surface oxidation treatment. Anodizing, electrostatic spraying, and baking paint are also available to meet decorative requirements.
The flat-blade diffuser features a prominent linear design, suitable for circular air inlets and outlets in indoor spaces or halls. It can also be installed on side walls or ceilings.
The blades are fixed, with a slanted air supply and return air type, and the blades are inclined at 15 degrees.
The maximum length of a single piece is 3 meters. Longer lengths can be achieved through splicing.
Optional accessory: G1 air volume control switch.
Face dimensions = Neck dimensions + 37 -
RA-2 Flat Blade Diffuser Performance Table
Neck Area
Air Speed (m/s)
2
3
4
5
6
7
0.0181m2
Total Pressure Loss (mmAq)
0.4
0.6
0.9
1.6
2.2
3.0
Air Volume (CMH)
130
194
260
324
389
454
Reach Distance (M)
Ceiling Discharge
0.1-0.1
0.8-0.8
1.6-1.6
2.1-2.3
2.8-3.1
3.3-3.6
Wall Discharge
1.2-1.6
1.8-2.8
2.8-3.8
3.3-4.8
4.0-5.4
4.2-6.0
NC
~
~
24
30
35
40
0.025m2
Air Volume (CMH)
180
270
360
450
540
630
Reach Distance (M)
Ceiling Discharge
0.3-0.3
1.2-1.2
2.0-2.2
2.6-2.9
3.5-3.8
4.1-4.4
Wall Discharge
1.3-2.0
2.2-3.2
2.8-4.1
4.0-5.1
4.6-6.0
5.2-6.7
NC
~
~
23
29
34
39
0.0324m2
Air Volume (CMH)
233
350
467
583
700
816
Reach Distance (M)
Ceiling Discharge
0.4-0.4
1.5-1.5
2.7-2.7
3.1-3.4
4.1-4.3
4.8-5.1
Wall Discharge
1.5-2.3
2.4-3.5
3.5-4.5
4.1-5.5
5.1-6.4
5.9-7.3
NC
~
~
22
28
33
38
0.0406m2
Air Volume (CMH)
292
437
583
729
875
1020
Reach Distance (M)
Ceiling Discharge
0.6-0.6
1.8-2.1
3.1-3.1
3.5-3.8
4.4-4.7
5.2-5.5
Wall Discharge
1.8-2.6
2.9-3.7
4.0-5.0
4.4-5.6
5.6-6.9
6.5-7.8
NC
~
~
23
29
34
39
0.0481m2
Air Volume (CMH)
346
520
692
866
1039
1212
Reach Distance (M)
Ceiling Discharge
0.9-0.9
2.0-2.0
3.2-3.2
3.9-4.1
4.8-5.2
5.6-5.7
Wall Discharge
2.2-2.8
3.1-4.1
4.3-5.3
4.8-6.1
5.9-7.2
6.8-8.4
NC
~
~
23
29
34
39
Note: Air outlet test length is based on 1M.
Note: Reach distance is measured at terminal air speed of 0.5M/S~0.25M/S.
Note: NC value column [-] indicates NC is below 20.
Note: NC value is based on indoor absorption attenuation of 10dB and 10-12 watts.
Note: Tested according to A.D.C. standard.
Note: If used for return air, static pressure loss = total pressure loss * 0.75 and NC value + 5.
Note: When the length changes, the reach distance and NC correction values are as follows:Effective Length (M)
0.5
1
1.5
2
NC
-2
0
+2
+3
Terminal Air Speed 0.5m/s
0.8
1
1.1
1.2
Terminal Air Speed 0.25m/s
0.9
1
1.15
1.2